Shenzhen Guangtong Optical Co.,Ltd

Tout
  • Tout
  • Titre
Accueil> Liste de Produits > Micro câble à souffler d'air> Microduct HDPE> HDPE 7ways Direct Buried Micro-conduit Microduct tuyau
HDPE 7ways Direct Buried Micro-conduit Microduct tuyau
HDPE 7ways Direct Buried Micro-conduit Microduct tuyau
HDPE 7ways Direct Buried Micro-conduit Microduct tuyau
HDPE 7ways Direct Buried Micro-conduit Microduct tuyau
HDPE 7ways Direct Buried Micro-conduit Microduct tuyau
HDPE 7ways Direct Buried Micro-conduit Microduct tuyau
HDPE 7ways Direct Buried Micro-conduit Microduct tuyau
HDPE 7ways Direct Buried Micro-conduit Microduct tuyau
HDPE 7ways Direct Buried Micro-conduit Microduct tuyau

HDPE 7ways Direct Buried Micro-conduit Microduct tuyau

Type de paiement:L/C,T/T,Paypal,others,Cash
Incoterm:FOB,CFR,CIF,EXW,FAS,FCA,Express Delivery
Quantité de commande minimum:1000 Meter
transport:Ocean,Land,Air,Express
Hafen:Shenzhen,Guangzhou

  • Attributs du produit
  • Emballage & livraison
  • Description du produit
  • Capacité d'approvisionnement et informa...
Attributs du produit

ModèleDB7

marqueSocle

Diameter16/12 14/10 12/8 10/6mm

Lengthcustomization

Ovality (%, Before Coiled)5%

Nom du produitmicroduct

MaterialHDPE

Service De TraitementExtrusion

Options De CouleurBlanc, rouge, vert, bleu entièrement coloré

Usageunderground installation

Épaisseur De Sous-canal2,0 mm

Épaisseur De La Gaine1,2 mm ou personnalisé

Emballage & livraison
Unités de vente: Meter
Type de colis: Package d'exportation standard, la longueur du tambour est de 2000 m ou personnalisé
Exemple d’image:

The file is encrypted. Please fill in the following information to continue accessing it

Description du produit
HDPE 7 façons de tuyau de micro-micro-micro-conduit enterré direct
DESCRIPTION DES PRODUITS POUR LE PIPE DE MICRODUCTE 7WAYS :
Microduct HDPE 7 Façons pour les fibres de soufflage d'air à installer par la jet aérien.
Poules de microduct composés de 18/14, 16/12, 14/10, 12/8, 10/6, 8/4, 7 / 3,5, sous-produits 5 / 3,5 mm, ou personnalisés. Le microduct intérieur est conçu pour être flexible et léger, mais durable et facile à manipuler. Le microduct a des caractéristiques de frottement faibles appropriées sur la surface intérieure.
Nom du produit: tuyau de microduct, tuyau de micro-conduit PE, tuyau de micro-conduit enterré direct
Détails Images pour le tuyau de microduct HDPE:
1 way microductmicroduct for fiber optic cablemicro module optical fiber cable
Spécification pour le tuyau de micro-conduit HDPE:
Raw material:
HDPE of a high-molecular type with the following parameters is used for production of the microduct:
Melt flow index
0.1~ 0.3 g/10 minutes  (190 C , 2.16KG)
EN ISO 1133
Density:
Min. 0.940 g/cm3
ISO 1183
Tensile strength at yield:
Min. 21MPa 
ISO 527
 l Elongation at the break
 Min 350% 
ISO 527
 l Environmental stress crack  
resist (F50)
Min. 350 hours
ISO 4599
Physical and Mechanical Properties of Sub-duct 18/14mm
1
Visual appearance
Visual inspection
Ribbed inside & smooth outside surface, free from blisters, shrink hole, flaking, scratches & roughness.
2
Outer diameter
GTOC
18.0mm ± 0.1mm
3
Wall thickness
GTOC
2.0mm ± 0.10mm
4
Inner diameter clearance
Blowing steel ball
A 10mm steel ball can be blown freely through the duct.
5
Ovality
GTOC
≤ 7%
6
Pressurization
5 minutes @12 bar each duct
No damage and leakage
7
Kink
IEC 60794-1-2 Method E10
≤ 180mm
8
Tensile strength
Rate of extension:
100mm/min
≥ 1800N
9
Impact
IEC 60794-1-2 Method E4
1.0 J Impact, recovery time 1 hour
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
10
Min. bend radius
216mm
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
Physical and Mechanical Properties of Sub-duct 16/12mm
1
Visual appearance
Visual inspection
Ribbed inside & smooth outside surface, free from blisters, shrink hole, flaking, scratches & roughness.
2
Outer diameter
GTOC
16.0mm ± 0.1mm
3
Wall thickness
GTOC
2.0mm ± 0.10mm
4
Inner diameter clearance
Blowing steel ball
A 10mm steel ball can be blown freely through the duct.
5
Ovality
GTOC
≤ 7%
6
Pressurization
5 minutes @12 bar each duct
No damage and leakage
7
Kink
IEC 60794-1-2 Method E10
≤ 160mm
8
Tensile strength
Rate of extension:
100mm/min
≥ 1600N
9
Impact
IEC 60794-1-2 Method E4
1.0 J Impact, recovery time 1 hour
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
10
Min. bend radius
192mm
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
Physical and Mechanical Properties of Sub-duct 14/10mm
1
Visual appearance
Visual inspection
Ribbed inside & smooth outside surface, free from blisters, shrink hole, flaking, scratches & roughness.
2
Outer diameter
GTOC
14.0mm ± 0.1mm
3
Wall thickness
GTOC
2.0mm ± 0.10mm
4
Inner diameter clearance
Blowing steel ball
A 8.5mm steel ball can be blown freely through the duct.
5
Ovality
GTOC
≤ 7%
6
Pressurization
5 minutes @12 bar each duct
No damage and leakage
7
Kink
IEC 60794-1-2 Method E10
≤ 140mm
8
Tensile strength
Rate of extension:
100mm/min
≥ 1350N
9
Impact
IEC 60794-1-2 Method E4
1.0 J Impact, recovery time 1 hour
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
10
Min. bend radius
168mm
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
Physical and Mechanical Properties of Sub-duct 12/8mm
1
Visual appearance
Visual inspection
Ribbed inside & smooth outside surface, free from blisters, shrink hole, flaking, scratches & roughness.
2
Outer diameter
GTOC
12.0mm ± 0.1mm
3
Wall thickness
GTOC
2.0mm ± 0.10mm
4
Inner diameter clearance
Blowing steel ball
A 8mm steel ball can be blown freely through the duct.
5
Ovality
GTOC
≤ 7%
6
Pressurization
5 minutes @12 bar each duct
No damage and leakage
7
Kink
IEC 60794-1-2 Method E10
≤ 120mm
8
Tensile strength
Rate of extension:
100mm/min
≥ 1200N
9
Impact
IEC 60794-1-2 Method E4
1.0 J Impact, recovery time 1 hour
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
10
Min. bend radius
144mm
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
Physical and Mechanical Properties of Sub-duct 10/6mm
1
Visual appearance
Visual inspection
Ribbed inside & smooth outside surface, free from blisters, shrink hole, flaking, scratches & roughness.
2
Outer diameter
GTOC
10.0mm ± 0.1mm
3
Wall thickness
GTOC
2.0mm ± 0.10mm
4
Inner diameter clearance
Blowing steel ball
A 6mm steel ball can be blown freely through the duct.
5
Ovality
GTOC
≤ 7%
6
Pressurization
5 minutes @12 bar each duct
No damage and leakage
7
Kink
IEC 60794-1-2 Method E10
≤ 100mm
8
Tensile strength
Rate of extension:
100mm/min
≥ 1000N
9
Impact
IEC 60794-1-2 Method E4
1.0 J Impact, recovery time 1 hour
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
10
Min. bend radius
120mm
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
Physical and Mechanical Properties of Sub-duct 8/4mm
1
Visual appearance
Visual inspection
Ribbed inside & smooth outside surface, free from blisters, shrink hole, flaking, scratches & roughness.
2
Outer diameter
GTOC
8.0mm ± 0.1mm
3
Wall thickness
GTOC
2.0mm ± 0.10mm
4
Inner diameter clearance
Blowing steel ball
A 5mm steel ball can be blown freely through the duct.
5
Ovality
GTOC
≤ 7%
6
Pressurization
5 minutes @12 bar each duct
No damage and leakage
7
Kink
IEC 60794-1-2 Method E10
≤ 80mm
8
Tensile strength
Rate of extension:
100mm/min
≥ 720N
9
Impact
IEC 60794-1-2 Method E4
1.0 J Impact, recovery time 1 hour
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
10
Min. bend radius
96mm
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
Physical and Mechanical Properties of Sub-duct 7/3.5mm
1
Visual appearance
Visual inspection
Ribbed inside & smooth outside surface, free from blisters, shrink hole, flaking, scratches & roughness.
2
Outer diameter
GTOC
7.0mm ± 0.1mm
3
Wall thickness
GTOC
1.75mm ± 0.10mm
4
Inner diameter clearance
Blowing steel ball
A 5mm steel ball can be blown freely through the duct.
5
Ovality
GTOC
≤ 7%
6
Pressurization
5 minutes @12 bar each duct
No damage and leakage
7
Kink
IEC 60794-1-2 Method E10
≤ 70mm
8
Tensile strength
Rate of extension:
100mm/min
≥ 630N
9
Impact
IEC 60794-1-2 Method E4
1.0 J Impact, recovery time 1 hour
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
10
Min. bend radius
84mm
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
Physical and Mechanical Properties of Sub-duct 5/3.5mm
1
Visual appearance
Visual inspection
Ribbed inside & smooth outside surface, free from blisters, shrink hole, flaking, scratches & roughness.
2
Outer diameter
GTOC
7.0mm ± 0.1mm
3
Wall thickness
GTOC
0.75mm ± 0.10mm
4
Inner diameter clearance
Blowing steel ball
A 3mm steel ball can be blown freely through the duct.
5
Ovality
GTOC
≤ 7%
6
Pressurization
5 minutes @12 bar each duct
No damage and leakage
7
Kink
IEC 60794-1-2 Method E10
≤ 50mm
8
Tensile strength
Rate of extension:
100mm/min
≥ 520N
9
Impact
IEC 60794-1-2 Method E4
1.0 J Impact, recovery time 1 hour
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
10
Min. bend radius
60mm
No residual deformation > 15% of inner and outer diameter, shall pass inner diameter clearance test.
Physical and Mechanical Properties (BUNDLE)
Tube Bundle
No. of ways
Outer Diameter
(Nom.)
Wall thickness
(mm)
Tolerance
(mm)
Max Tensile
(N)
HDPE 2x 18/14mm
2
38.4mm
1.2
±0.20
weight*G
HDPE 2x 16/12mm
2
34.4mm
1.2
±0.20
weight*G
HDPE 2x 14/10mm
2
30.4mm
1.2
±0.20
weight*G
HDPE 2x 12/8mm
2
26.4mm
1.2
±0.20
weight*G
HDPE 2x 10/6mm
2
22.4mm
1.2
±0.20
weight*G
HDPE 2x 8/4mm
2
18.4mm
1.2
±0.20
weight*G
HDPE 2x 7/3.5mm
2
16.4mm
1.2
±0.20
weight*G
HDPE 2x 5/3.5mm
2
12.4mm
1.2
±0.20
weight*G
*Customization service available for different sheath thickness or different number of sub-ducts.
Technique de fabrication pour le tuyau de microduct 4WAYS
Manufacturing Technique
Standards:
Crush performance
IEC 60794-1-2-E3
Tensile & elongation
IEC 60794-1-2-E1
Bend
IEC 60794-1-2-E11
Flexibility
IEC 60794-1-2-E8
Kink
IEC 60794-1-2-E10

Stockage:

Les packages complétés du microduct HDPE sur les tambours peuvent être stockés en plein air max. 12 mois après la date de production. Température de stockage: -40 ℃ à + 70 ℃ Température d'installation: -20 ℃ à + 50 ℃ Température de fonctionnement: -40 ℃ à + 70 ℃
Emballage et fabrication de produits:
low friction microduct24 way microduct
Projet:
micro duct microductHDPE 1.2mm micro duct
Capacité d'approvisionnement et informa...

Détails d'emballagePackage d'exportation standard, la longueur du tambour est de 2000 m ou personnalisé

productivité600000 Meter/Meters per Month

transportOcean,Land,Air,Express

Lieu d'origineChine

Soutenir600000 Meter/Meters per Month

Certificats ISO,ROHS

Code SH3917210000

HafenShenzhen,Guangzhou

Type de paiementL/C,T/T,Paypal,others,Cash

IncotermFOB,CFR,CIF,EXW,FAS,FCA,Express Delivery

Accueil> Liste de Produits > Micro câble à souffler d'air> Microduct HDPE> HDPE 7ways Direct Buried Micro-conduit Microduct tuyau
  • Envoyer Une Demande

Copyright © 2024 Shenzhen Guangtong Optical Co.,LtdTous droits réservés.

Envoyer Une Demande
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

envoyer